What to Do If It's Leaking
Emergency steps: what to shut off and when to call.
A puddle under the tank most often means the tank itself has failed — and that usually means replacement. But the same puddle can come from a leaking drain valve, an electric element gasket, the relief valve discharge pipe, or just condensation. Finding the exact source is the key step.
Shut off the cold water and power or gas first, then do the dry-rag test below.
| Cause | How to tell | Fixable? |
|---|---|---|
| Failed or corroded tank | Puddle at base, no leaking valve or pipe above; often rust streaks; heater is older | No — replace |
| Leaking drain valve | Drip from the small spigot near the bottom | Yes — tighten or replace the valve |
| Electric element gasket or loose element | Moisture around the element access cover on an electric heater | Yes — replace gasket or element |
| T&P discharge pipe end | Water from the pipe running down the side (not the tank) | Yes — see T&P guide |
| Condensation | Light surface moisture while heating cold water; stops on its own | Normal |
| Leak above running down | Wet insulation or drips trace back to a higher fitting | Yes — repair upper fitting |
Inside a steel tank a sacrificial anode rod is designed to corrode first. Once it is used up, the tank can start to corrode. The City of Prescott reports moderately hard water (about 4.3 to 7.6 grains per gallon), so mineral scale builds up over time. That scale can cover the bottom element or burner and accelerate wear. Regular flushing and anode rod checks help. See maintenance.
Tank heaters are often said to last roughly 8 to 12 years. The manufacture date is coded in the serial number on the label. If the heater is past its expected life and leaking from the base, replacement is usually the practical choice. In Prescott, a permit is required. See installation for what to expect.
A leaking drain valve or element gasket can be repaired. A leak from the tank body cannot be patched and the heater should be replaced.
Light moisture while a cold tank heats up is normal and will stop. A steady drip or growing puddle is not condensation.
If the leak is active, shut off cold water and power or gas immediately, then call for help. See the emergency steps.
Prescott Water Heater Experts is a referral service, not a licensed plumbing contractor. Providers are independent and responsible for their own licensing, pricing and workmanship.
Call 877-722-6903 for repair or replacement help.